Меню каталога
Закрыть

IVF Workstations Class II Type A2

IVF Workstations Class II Type A2
Производитель:
LAMSYSTEMS

Поделиться в соц.сетях:
IVF Workstations Class II Type A2LAMSYSTEMS
Количество
Полное описание
Highly pure air environment is created in the work chamber to protect valuable samples, environment, and operator during АRT.

- AII brands of microscopes сап be installed
- Curtain for microscope
- Single-piece tabletop сап be equipped with gas-springs for convenient disinfection
- Armrest
- Additional options: gas supply and humidification system, 21.5" monitor 
















 Position of the front sash and the UV                         Monolith tabletop can be lifted           unit affecting the protective properties                      with gas-springs for convenience              of the device is controlled by                                      of the disinfection process                     high-precision optical sensors








А pullout UV lamp is located outside                               Additional options: technical             of the work chamber and does not                                   and inflammable gas taps,            impact the airflows during operation                                             vacuum tap

                 

                      AIR FLOW SCHEME                                     VARIATIONS OF HEATED SURFACE                                                                                                   LOCATION AND ARRANGEMENT







TECHNICAL SPECIFICATION 

Air cleanliness class in the work chamber for suspended particle (aerosol) concentration according to ISO 14644-1

Class 5

Class of the cabinet according to EN 12469, NSF/ANSI 49

II

Туре of the cabinet according to NSF/ANSI 49

A2

Class of the НЕРА filters according to EN 1822-1

H14

Primary efficiency of НЕРА filters for particles sized 0.3 µm according to EN 1822-1, %

99,995

Average downflow velocity in the work chamber in operating mode / 50% mode, m/s

0,28±0,02 / 0,20±0,02

Work zone illumination, lx, not less than

2000

Air recirculation, %

70


Modes of Operation: 
Set-up - blowdown ............................................................ Maximum fan rotation for 1 min  
Operating mode ........................................................... Specified operating airflow velocity 
Clean maintenance mode .... Fan in economy mode, lighting and other functions аre off 
Economy mode ........................................................................................... 50% fan capacity  

Warm-up bу specified time                                                                          preset with timer 

HEATED SURFACES 

Preset temperature range, 0С

+35 to +45

Accuracy of preset temperature maintenance, 0С                                              

±0,3


MAIN PARAMETERS AND DIMENSIONS

Article

1 Е-8.006-09.0

1 Е-8.006-12.0

1 Е-8.006-15.0

Dimensions of the caЬinet assemЫed with the stand (WxDxH), mm

1000х770х2095

1200х770х2095

1500х770х2095

Dimensions of the work chamber (WxDxH), mm

905х610х750

1105х610х750

1405х610х750

lnput power of the cablnet, W, not more than (exclusively of the load оп the built-in outlets)

900

1150

1150

Maximum ассерtаЫе load оп the built-in outlets, W, not more than

1000

1000

1000

Power of the UV lamp, W

25

30

30




Брошюры

IVF Workstations
скачать файл